PNL EW-CAC-HT – Panels for Measurement of Chlorine or Chlorine Dioxide in Hot Water
DESCRIPTION
STEIEL offers a wide range of “turnkey” solutions, including instrument and measurement sensors assembled on panel.
The more complex systems are also equipped with an adjustment dosing pump and / or data recording / managing device.
These models have been designed for measuring chlorine or chlorine dioxide in domestic hot water systems, with a three-electrode open amperometric cell.
The standard panel is provided with filter for hot water; upon request, for installations with sample water recovery, version is available with hydraulic circuit complete with recirculation pump, valves and manometers.
TECHNICAL DATA
- Panel with four holes for wall mounting
- Customizable graphic layout on request
- The basic system includes:
- EVOLUTION EW instrument with input configured for CAC-HT-B sensor
- CAC-HT-B probe, open amperometric with three electrodes, and specific electrolyte
- Pt100 temperature sensor, for temperature displaying
- Down-flow type, methacrylate probe holder with inlet flow regulation, proximity sensor and sampling outlet
- Filter with steel mesh cartridge for use in hot water
- Depending on the application needs, these panels can be also equipped with a dosing pump and/or an hydraluci circuit for the recovery of sample water coming out from the probe-holder
- Working conditions: temperature max 70 °C @ 3 bar; max 50 °C @ 6 bar
- Upon request, the SteieLynx supervisor is available, even as module to be integrated in the EW unit
LOGIN / REGISTER
To access to the download area
CONTACT US
To request more info about our products