PNL EW-CAC – Panels with CAC Probe, for Water Disinfection

DESCRIPTION

STEIEL offers a wide range of “turnkey” solutions, including instrument and measurement sensors assembled on panel.

The more complex systems are also equipped with adjustment dosing pump(s) and / or data recording / managing device.

This series has been designed for the analysis (and control) of disinfectant concentration in water, with a membrane closed amperometric cell, which – depending on model – allows to measure the level of chlorine (active, available, total; even in sea water), chlorine dioxide, bromine, peracetic acid, chlorite, ozone, hydrogen peroxide.

These systems are widely used in the purification, sanitation and continuous disinfection of water distribution systems and networks.

TECHNICAL DATA

  • Panel with four holes for wall mounting
  • Panel dimensions:
    • 595 x 750 mm, with one pump
    • 900 x 700 mm, with two pumps
  • Customizable graphic layout on request
  • The basic system includes:
    • Evolution EW instrument with mV/mA input
    • CAC series probe, closed amperometric, with selective membrane and specific electrolyte; thermo-compensated readings thanks to the inbuilt temperature sensor
    • Optional Pt100 temperature probe, for temperature displaying
    • Flow-through, methacrylate probe holder with inlet flow regulation, proximity sensor, and sampling outlet
    • Filter with mesh cartridge
  • Depending on the application needs, these panels can be also equipped with dosing pump(s)
  • Upon request, the SteieLynx gateway for remote managing of the system, as external unit or integrated module

 

 

 

LOGIN / REGISTER

To access to the download area

CONTACT US

To request more info about our products